Diabetes · For patients and their doctors
Your glucose sensor records hundreds of readings a day. Upload the file your sensor app exports, or type in the numbers from the first page of your report, to see how much time you spend in range, when your lows happen, what your typical day looks like, and what to do next.
A guide to discuss with your doctor, not a prescription. Do not change insulin or other medicine doses from this page. The file is read on your phone or computer and is never uploaded anywhere.
"Older or at high risk" is for people who are frail, have many other illnesses, or have had severe lows. Your doctor can tell you which fits.
Choose your CSV file, or drop it here.
Works with FreeStyle Libre (LibreView), Dexcom Clarity and Medtronic CareLink exports, and most other CSV files with a time and a glucose column.
.
Caspian Healthcare reception: 89193 41154. Sensors are available from the Caspian Pharmacy: 85198 41154.
| Group | In range | Below range | Above range |
|---|---|---|---|
| Type 1 and type 2 (and children, ISPAD 2024) | 70 to 180: above 70% | below 70: under 4%; below 54: under 1% | above 180: under 25%; above 250: under 5% |
| Older or high risk | 70 to 180: above 50% | below 70: under 1% | above 250: under 10% |
| Pregnancy, type 1 | 63 to 140: above 70% | below 63: under 4%; below 54: under 1% | above 140: under 25% |
| Pregnancy, type 2 or GDM | 63 to 140: no set percentage | keep to a minimum | keep to a minimum |
CV 36% or less for all groups. Data: 14 days with at least 70% capture (10 days with 80% or more is acceptable). Events start after 15 minutes beyond a threshold and end after 15 minutes back. GRI = 3.0 × (very low + 0.8 × low) + 1.6 × (very high + 0.5 × high), zones A to E in steps of 20. Pattern prompts (overnight fall of 50 mg/dL, meal rise of 50 mg/dL, interquartile range of 90 mg/dL) are rules of thumb, not consensus values.
Found an error? Write to info@caspianhealthcare.in.